THE STATION - CONSTRUCTION OF A NEW THREE STORY MIXED-USE BUILDING ON A VACANT SITE WITHIN THE HISTORIC URBAN CORE OF MATTHEWS, MECKLENBURG COUNTY, NC. BUILDING COMPRISES UNOCCUPIED SHELL SPACE AT ALL LEVELS FOR FUTURE FIT-UP AS MERCANTILE OR A-2 RESTAURANT OCCUPANCY AT THE GROUND FLOOR, AND FUTURE BUSINESS SPACE AT THE SECOND AND THIRD FLOORS WITH A SMALL AMOUNT OF FUTURE A-2 USAGE AT THE THIRD FLOOR LINKED TO AN OPEN ROOF TERRACE. TWO ELECTRICAL SERVICES; SERVICE 1 OR 2 FOR 2ND AND 3RD FLOORS RATED AT 1,200A, 208Y/120V, 3-PH, 4-WIRE; SERVICE 2 OF 2 FOR 1ST FLOOR RETAIL TENANTS RATED AT 1,000A, 208Y/120V, 3-PH, 4-WIRE. SERVICE 1 OF 2 WILL CONSIST OF A 1,200A MAIN DISTRIBUTION BOARD LOCATED IN THE FIRST FLOOR UTILITY ROOM AND 8 SUB-PANELS THROUGHOUT THE BUILDING FOR HOUSE LOADS AND 2ND AND 3RD FLOOR TENANT. VAV ROOFTOP UNITS ARE TO BE PROVIDED FOR SPACE FITOUT ON THE 2ND AND 3RD FLOORS. EXHAUST AND VENTILATION DUCTS ARE PROVIDED FOR FUTURE TENANT USE WHEN FITTING OUT RETAIL SPACES ON THE FIRST FLOOR. INSTALLATION OF A 3 INCH CW SERVICE TO THE BUILDING. A 1 ?? SERVICE IS PROVIDED TO EACH OF 5 FIRST FLOOR RETAIL TENANTS. WATER IS ALSO PROVIDED UP A CENTRAL CHASE FOR USE ON THE 2ND FLOOR, 3RD FLOOR, AND ROOF. A 4 INCH SANITARY LINE IS PROVIDED TO THE BUILDING. EACH OF THE 5 FIRST FLOOR TENANT WILL HAVE A 4 INCH SANITARY LATERAL. A 4-INCH SANITARY RISER RUNS UP THE CENTRAL SHAFT OF THE BUILDING. PROVISIONS FOR FUTURE GREASE TRAPS SERVING THE FIRST AND 3RD FLOORS ARE INCLUDED ALTHOUGH NOT THE GREASE TRAPS THEMSELVES. NATURAL GAS SERVICE IS PROVIDED FOR BASIC BUILDING HVAC ALONG WITH PROVISIONS FOR FUTURE TENANT USES ON THE FIRST AND THIRD FLOORS.